// Language switcher on every page: EN default navI18n unless a locale // page supplied its own. Non-translatable paths link the menu to each homepage. const navI18n = options.navI18n || (() => { const L = uiFor('en'); const m = (options.seoHeadTags || '').match(/rel="canonical" href="([^"]+)"/); const path = m ? m[1].replace(/^https?://[^/]+/, '') : '/'; const translatable = TRANSLATED_PATHS.some(re => re.test(path)); const entries = [{ code: 'en', host: 'hengxang.com', name: 'English' }, ...LOCALES]; return { t: L, currentName: 'English', path, langItems: entries.filter(e => e.code !== 'en') .map(e => '
  • ' + e.name + '
  • ').join(''), }; })();

    Fiber Optic Splice Closure Manufacturer

    HENGXANG molds and assembles fiber optic splice closures in Yiwu, Zhejiang - dome closures to 48 cores and beyond, horizontal three-tier inline closures, aerial junction boxes with splitter space, and underground PPR boxes. Every shell seals to IP68, every gasket re-enters, and every unit passes an air-pressure seal test before it packs.

    The closure is the most exposed part in the network: it lives underground, underwater, on poles and inside pedestals, holding the network's most fragile points - the splices. Choosing a fiber optic splice closure manufacturer is a sealing decision, not a price decision. This fiber optic splice closure manufacturer has molded and tested that protection since December 2000, with 100% seal testing on every production batch.

    This page from a certified fiber optic splice closure manufacturer lists the closure families with MOQ and lead time, the dome-versus-horizontal choice, the sealing and re-entry specs, OEM capability, certifications and factory facts - then the questions buyers ask first. Send your route plan and the export desk replies with a written quote within 24 hours on business days.

    Home / Prodotti / Fiber Optic Splice Closure

    Fiber Optic Splice Closure Products

    Closure Families: Specs, MOQ and Lead Time

    Every closure family this fiber optic splice closure manufacturer molds and tests is listed below with MOQ and lead time. Lead time runs from deposit and includes the air-pressure seal test on 100% of units.

    FamilyOptionsCapacityMOQLead time
    Dome closure (vertical)Multi-port entries, gland or heat-shrink seals24-48+ cores200 pcs6-9 days
    Horizontal inline closureThree-tier tray stack, 2-4 cable entries24-48 cores200 pcs6-9 days
    Aerial junction box1x8 splitter space, steel-tube splitter ready24 cores + splitter200 pcs6-9 days
    Underground PPR boxPPR body, 4-port, handhole ratedSmall joints200 pcs6-9 days
    FTTA cassette enclosureCassette style, splitter + splices, 6-core entries6-24 cores200 pcs6-10 days
    LGX splitter housingWaterproof 1x8 LGX mount, SC/APC portsSplitter + 8 drops200 pcs6-9 days

    MOQ and lead-time figures are standard production windows; Chinese New Year peaks can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.

    What buyers order most from this shelf

    These five cover most purchase orders. Port configurations, seal types and mounting brackets set per order - the grid above lists the current shells.

    Dome or Horizontal? Choose by Route Shape

    Both closures seal the same joints - the shape follows the route, and this fiber optic splice closure manufacturer builds both families on shared tray hardware:

    Dome (vertical)Horizontal (inline)
    ShapeCable enters the base, dome liftsCable enters both ends, body splits
    CapacityHighest - stacked trays24-48 cores across three tiers
    Entries4-8 ports around the base2-4 ports, two ends
    Best routeTrunk joints, branch points, pedestalsStraight distribution runs
    Re-entryLift the dome - hands stay freeOpen the clamshell in place

    Mixed routes use both: a dome at the branch point, horizontals along the run. Because both families share the same splice tray system, trays and protectors stock as one spare set.

    Anatomy of a Dome Closure: Seven Parts Between Water and Glass

    Lift the dome and seven parts do the protecting. Buyers who know them read a closure like a spec sheet:

    Horizontal closures run the same seven parts laid inline, with the tray stack split across three tiers instead of one column.

    Splice Tray Organization: Where 48 Splices Stay Calm

    A 48-core closure holds four 12-splice trays stacked on posts. The organization rules that keep future crews friendly:

    Stacked trays hold under a lid with clearance above the highest protector - the dome never touches glass, and neither does the crew's patience.

    Sealing and Re-Entry: The Specs That Decide a 20-Year Closure

    A closure fails in one place first - the seal. Four specs keep water out for two decades:

    Proof, not promises: every unit from this fiber optic splice closure manufacturer leaves the line through an air-pressure seal test - the housing pressurizes, and the pressure holds before the unit earns its box.

    Three Seal Types: Gland, Heat-Shrink or Gel - Pick by Crew and Route

    Port sealing is where closures get specified, and each seal type suits a different crew and route:

    Seal typeHow it worksBest for
    Mechanical glandA compression ring squeezes the port seal onto the cable - re-openableMaintenance-heavy routes and re-entry plans
    Heat-shrinkAn adhesive tube shrinks onto cable and port - permanent bondBuried routes opened once in a decade
    Gel sealA gel block wraps the cable - tool-free and reusableFast drop programs and mixed cable sizes

    Mixed orders are normal: gland seals on the feeder entries, gel seals on the drop entries, in one closure. State the cable diameters per port in the RFQ and the quote lists the seal per port - this is the level of detail a fiber optic splice closure manufacturer should volunteer, not chase.

    Plan the Spare Ports: Growth Costs Nothing at Order Time

    Closures seal ports permanently once heat-shrink sleeves go on - so port count is a five-year decision made at order time. Three planning habits keep growth cheap:

    Send the route plan with today's joints and the growth plan, and the quote states the capacity we would ship - spare plugs gasketed and bagged inside the dome.

    Port Seal Configuration: Send Diameters, Get a Schedule

    The RFQ that seals best asks one extra question: what cable diameter enters each port? Quote teams return a port schedule like this (illustrative):

    PortCableSeal
    Entry 112.0 mm feederHeat-shrink, permanent
    Entry 210.0 mm feederHeat-shrink, permanent
    Entry 37.0 mm distributionGland ring, re-enterable
    Entry 47.0 mm distributionGland ring, re-enterable
    Entries 5-6ReservedBlank plugs, gasketed

    Reserved ports ship with gasketed plugs, so a future cable enters through a factory seal instead of a field improvisation. The schedule prints into the order and packs in the box - the next crew inherits the plan, not a puzzle.

    OEM, ODM and Private-Label Capability

    As an OEM fiber optic splice closure manufacturer, we build to your port layout, marking and packaging spec:

    OEM projects we shipped (draft references - replace with your approved cases)

    “We reopened two closures for a reroute after a year underground - new gaskets in, pressure test passed again.” - jointing supervisor, African FTTH program (draft testimonial - replace with your approved reference).

    “Every dome arrived pressure-tested with its own record. Our acceptance dropped to a spot check.” - quality lead, European utility contractor (draft testimonial - replace with your approved reference).

    Closures work beside the boxes that end the cable: see our termination boxes for the drop point and ODFs for the exchange.

    Certifications and Compliance

    The factory runs under ISO 9001:2015, with CE reports covering passive families sold into the EU, and the company holds a utility patent on a fiber optic quick connector - the in-house R&D behind our passive range. Documents are public on the certificate page.

    CertificateRelevance to closures
    ISO 9001:2015Quality management for molding, assembly and seal testing
    OHSAS 18001:2007Occupational health and safety management
    CE reportsPassive families shipped into the EU
    Utility model patentQuick connector design - the factory's R&D depth

    Materials run RoHS-compliant on request; shells are UV-stabilized PC rated for -40°C to +65°C service. RoHS certificates join the shipment file on request.

    Factory Strength: Seals Proven on a Bench, Not a Promise

    A closure is a pressure vessel with fiber inside, and this fiber optic splice closure manufacturer treats it like one. The Yiwu compound molds shells, cuts gaskets and runs the seal-test bench beside our cable and cord lines - 25 years under founder LING LI, since December 2000:

    Company quick facts
    FoundedDecember 2000, Yiwu City, Zhejiang, China
    FounderLING LI, Founder & General Manager
    FocusClosures, termination boxes, splitters, connectors, adapters, cords, cable, ODFs
    Export markets40+ countries across Asia, the Middle East, Africa, Europe and the Americas
    Response timeQuotes within 24 hours on business days

    Four Closure Failures and the Detail That Prevents Each

    Closures from careless fiber optic splice closure manufacturer lines fail in known ways. Each failure maps to a build detail on our line:

    Four failures, four details - all visible on the bench before shipment, which is why the air-pressure test record matters more than the product photo.

    Documentation: The Paper Trail of a Sealed Joint

    Acceptance teams audit paper as hard as they audit seals. Every closure order produces three documents:

    Records keep for the warranty period and match the serial labels on the housings - the paper trail ends where the closure begins.

    Regional Notes: Closures Ship Differently by Market

    Twenty-five years of export taught this fiber optic splice closure manufacturer how routes and habits change the spec by region:

    Tell us the route type and the crew profile. We answer with the build that already ships there.

    Why Buyers Pick HENGXANG Over Other Suppliers

    Closure quality hides until the first flood. Compare on the specs that decide it:

    FactorHENGXANGTypical trading company
    Seal proof100% air-pressure test, record per unitNo per-unit test
    Re-entryGasket-cut mechanical seal, spares stockedSingle-use seals
    Port sealingGland or heat-shrink, sized to your cableOne generic oval port
    MOQ200 pcs per family, mixed models share the run1,000 pcs minimums
    Quote speedWithin 24 hours on business daysDays
    RangeClosures + boxes + splitters + cable, one orderSingle category

    And one habit worth naming: we ask for the cable diameters before quoting port seals. A closure port that does not match your cable is a leak designed at the quote stage - and we would rather design it out.

    How We Work With You: From Route Plan to Loaded Pallets

    Six steps, all written down:

    Worked Example: Sealing a 120-Kilometer Feeder Route

    Illustrative figures - your quote states yours. A contractor joints a 120 km feeder with 60 splice points and orders accordingly:

    StepDetail
    Route review48 dome closures for trunk joints, 12 horizontal for distribution taps
    Port sealsGland rings sized to the 12 mm feeder and 10 mm drop cables on the route
    Production8 days: molding, gasket fitting, tray stacking per closure
    Seal testDays 8-9: 100% pressurize-and-hold on 60 units; records filed per serial
    ShipmentDay 10: palletized with splice protectors and gasket spares, FOB Ningbo

    Ten days to a sealed, documented pallet set - and 60 pressure records in the file when the acceptance team asks. That is what ordering from a fiber optic splice closure manufacturer with its own test bench buys you.

    FTTA Note: Closures at the Tower Base

    Radio-unit fiber runs need small, sealed, low-count terminations at the tower base - and the FTTA cassette enclosure on this shelf exists for exactly that point:

    Programs that mix FTTA enclosures with aerial junction boxes order both from this shelf - one part numbering scheme across the whole site build.

    Emergency Note: Storm Repairs Run on a Different Clock

    Storm damage does not wait for production windows. Stocked closure types ship emergency quantities in 48-72 hours (draft program - confirm current stock with sales), packed as crew kits: closures, gasket sets, port plugs and splice protectors in one box per jointing team. Programs that keep a two-joint kit per crew van turn a storm week into a work order instead of an outage report.

    Seal the Route, Then Run the Whole Shelf

    Closures guard the joints; the same factory ships everything between them: the cable on the route, the splitters that fit inside splitter-ready closures, the termination boxes at the buildings, the patch cords and connectors at every end, and the ODFs at the exchange. Level trouble on the run? Attenuators trim the hot ports, and the ODF planning guide maps the exchange before it locks. One purchase order, one freight plan, one warranty conversation.

    Frequently Asked Questions

    What is a fiber optic splice closure used for?

    It protects the point where two or more cables are fusion-spliced together mid-route - the joints, the splice protectors and the stored slack fiber. The closure seals those joints against water, dust and temperature for decades. Without one, a buried or aerial joint fails within its first wet season.

    What is the difference between dome and horizontal closures?

    Dome closures are vertical - the cable enters the base and the dome lifts off for access; they hold the highest fiber counts and suit aerial, buried and pedestal builds. Horizontal closures are inline - cable enters both ends, and the body opens in the middle. Dome rules high-count trunk routes; horizontal rules distribution runs with two to four cables.

    How many fibers fit in one closure?

    It follows the splice tray stack. Our trays hold 12 splices each, and trays stack in the housing: 24-core and 48-core builds are standard, and larger stacks cover 96-splice retrofits. Size the closure by today's splices plus your planned future joints - re-entry is designed in, but capacity is not infinite.

    Can the closure be reopened without damage?

    Yes. The mechanical seal re-seals on re-entry, and the gasket is cut for repeated opening - that is the point of a re-entry design. Gaskets stock as spare parts, so a maintenance reopen costs a gasket, not a closure.

    What does IP68 mean for a splice closure?

    IP68 is the highest common sealing rating: fully dust-tight and able to survive continuous submersion. Our closures test under water at pressure equivalent to 1 meter of submersion for extended periods (draft test condition - datasheets state the exact protocol). Buried and underground closures should always carry IP68.

    Do the closures come with factory-fitted splitters?

    Yes on the splitter-ready models - a 1x8 LGX box or steel-tube splitter seats inside the dome beside the splice trays, and every drop port reads its own loss on the test sheet. Standard splice-only models stay available for routes without a split point. State the ratio and we confirm the interior layout in the quote.

    What is your MOQ for splice closure orders?

    All closure families start at 200 pieces per model. Mixed models - domes, horizontal and aerial junction boxes - share one production run and one container. Splitter-ready builds with LGX housings start at 200 pieces as well.

    How long does a splice closure order take?

    Standard domes and horizontal closures from this fiber optic splice closure manufacturer ship in 6-9 days; splitter-ready and FTTA builds in 6-10 days. Every unit passes an air-pressure seal test before packing, and the test record ships with the goods. Bulk rollout orders phase against your construction calendar.

    Do the closures hold splitters as well as splices?

    Yes. Splitter-ready models carry an LGX housing or steel-tube splitter inside the dome alongside the splice tray - one closure serves the split point and the joints around it. Tell us the splitter ratio and we confirm the interior layout in the quote.

    Splitter-Ready Closures: The Distribution Point in a Dome

    Six of the families on this shelf are pure splice closures; two go further. Splitter-ready models carry a 1x8 LGX box or a steel-tube splitter inside the dome beside the splice trays:

    For districts that would otherwise mount a separate splitter box beside the closure, the integrated build removes one housing, one visit and one leak risk. It is the closing argument a fiber optic splice closure manufacturer makes on rollout economics.

    Accessories That Ship With Every Order

    Each closure carton carries the mounting and sealing kit: dome-base bolts, gasket spares, port plugs for unused entries, stainless bond lugs, and the instruction card. Heat-shrink sleeve sets and gasket refill packs order as line items - crews that re-enter closures keep a gasket kit in the van, and we stock it to match your closure serials. Port plugs, grounding lugs and tray labels ship in the same kit, so a crew with one van box can joint, seal and document without a second order.

    Get Your Splice Closure Quote Today

    Send your closure types, port counts and cable diameters. Your quote with prices, MOQ, lead time and packing plan arrives within 24 hours on business days. Free samples - dunk test welcome at your own bench.

    Request a Quote Now

    WhatsApp: +86 134 3434 9304  |  Email: peter@hengxang.com

    Contact By Whatsapp